CertifiedCopyright 2011 Nyce Control Incorporated. All rights reserved.Control4 certified on 1/3/2012 for software released versions: 2.0.6 2.1.0
Driver version: 1.1.0\n
Instructions for setting up NCZ-3011\n
1) Add the Control 4 contact switch driver from My Drivers-Sensors-Contact Switch and connect the two drivers in the Control/AV tab of the Connections window.\n
2) In Connections screen under the Network tab, double click on the driver name to identify the device. When the identify window opens, follow the instructions to identify the device (4 button presses). If the device identifies successfully, its 64-bit (16-character) address should show up in the identify window text box.\n
3) In the left window of the System Design screen, select the Nyce Contact Switch Driver. The Enrollment Status field in the Properties tab of a joined device should read: Successful Enroll. Note that it may take up to 20 seconds after a successful identify for Enrollment Status to update.\n
4) If after more than 20 seconds, the Enrollment Status still reads: Unenrolled, execute a leave (6 button presses) and repeat the join procedure in step 4.\n
5) After a successful enroll, Sensor State and Battery State will continue to read: Unknown until the first sensor event. After the first sensor event, these fields should update each time the sensor opens and closes. The corresponding UI icon under the List View tab of the System Design window should also update with every sensor event.\n
\n
Release Notes for NCZ-3011 Version 1.1.0\n
1) A leave is accomplished by 6 button presses.\n
2) A leave and restore to factory defaults is accomplished by 10 button presses.\n
3) Two button presses cause device to indicate network connectivity:
-two GREEN flashes: joined to network
-two RED flashes: not joined to a network\n
4) Other LED Functions:
-Single GREEN flash: button press
-Single ORANGE flash: unsupported number of button presses, no action\n
5) The device can rejoin the same network if moved to another channel.\n
6) The device will first scan the HA Profile recommended channels, namely channels 11, 14, 15, 19, 20, 24, and 25. If no network is found, the remaining channels will be scanned.\n
7) If a device is reporting that it is joined to a network, but is not operating as expected, execute a leave (6 button presses), and retry the join procedure.\n
8) A Disconnect issued by the director must be accompanied by a Leave (6 button presses) on the device unless the device is awake to receive the directors Leave Request.\n
9) If a device is not responsive, first try power cycling the device by removing its battery momentarily. If the device does not recover, execute a factory restore (10 button presses).\n
Press the identify button on the Nyce Control NCZ-3011 Contact Switch FOUR times.Debug ModeLIST- Off
- Print
- Log
- Print and Log
OfffalseSensor StatusSTRINGOfflinetrueEnrollment StatusSTRINGUnenrolledtrueSensor StateSTRINGUnknowntrueBattery StateSTRINGUnknowntrueHA Profile Contact Switchdevices_sm/contact.gifdevices_lg/contact.giflua_genDriverWorksSensorsDriverWorks_HA_Profile_CSwitchtrueothersc4:NyceControl:NCZ-301150016Contact2FalseFalseFalseFalseCONTACT60016ZIGBEE4TrueFalseFalseTrueZIGBEE106Contact DI 01FalseFalseFalseTrueCONTACT_SENSOR1Battery LowWhen NAME battery is low2TroubleWhen NAME failure is imminentNyce Control110Nyce Control11/17/2010 12:30 PM11/29/2011 11:00 AMNCZ-3011Control4 certified on 1/3/2012 for software released versions: 2.0.6 2.1.0zigbee