Copyright Extra Vegetables LTD. All rights reserved.CoolMasterCoolLink (No Schedule) - FREECoolLink (No Schedule)Extra Vegetables10/25/2010 13:3009/10/2014 12:00800lua_genDriverWorks Copyright Extra Vegetables LTD. All rights reserved. 8.0.0 EXTRA VEGETABLES DRIVER FOR COOLINK This driver enables a Coolink unit to be represented on Control4 UI as a thermostat and does not include scheduling capabilities. ---------------------------------- BRIEF INSTRUCTIONS - Make the connection to the Serial port to which the CoolLink is connected. - Set the TEMPERATURE end point connection to this driver for the room in which it is reporting. - Set the TEMPERATURE_CONTROL end point connection to this driver for the room in which it is controlling. - Refresh the Navigators ---------------------------------- FULL INSTRUCTIONS Full instructions for this driver are included in the download package. You can download the instructions by logging into the Extra Vegetables website at www.extravegetables.com and downloading the driver package. ---------------------------------- SUPPORT For support on this driver please contact Control4 technical support or your local Control4 distributor. ---------------------------------- AUTO UPDATE This driver supports Auto Update. To enable this feature select Automatic Updates to 'On'. ---------------------------------- CHANGELOG 8.0.0 Sep 10 2014 Activation key removed 7.1.5 - 20 June 2014 Enables the selection of . or , as the local decimal separator. This MUST be set to the correct character for your controllers locale. 7.1.4 - 18 December 2013 Corrects an issue in determing the expected temperatures at a time point in a schedule. 7.1.1 - 6 November 2013 Corrects an issue where the locale decimal separator is , 7.1.0 Driver now follows Cooling schedule in Cooling Mode. Can now choose which schedule to follow in Auto mode. Coolmaster only has single set point ability. When moving between modes system will adopt scheduled temperature for the mode selected. 7.0.9 23 July 2013 Resolves issue with scale changes not being honored 7.0.8 12 July 2013 Adds persist data and hold mode support Resolves issue with fan speed from fan mode UI not working 7.0.7 15 May 2013 Enables hold modes in driver. Will set CoolLink to previously saved values on system reboot. 7.0.6 29 April 2013 Compatible with changed isEnabled notification in OS 2.4 7.0.5 18 March 2013 Makes compatible with new firmware in units that are not providing scale information with airt temperature reading. Backwards compatible. 7.0.4 1 February 2012 Enables Low, Medium, High and Auto fan modes from the Control4 UI On/Top fan speed can still only be set from programming as Control4 does not allow us to enable all of the fan modes on the UI. NOTE: You need to restart the controller after an Auto Update in order to enable this feature! 7.0.3 January 23 2013 Adds a little extra to command delay, prevents issues when being used with Thermostat Combiner on new faster controllers. 7.0.2 November 7 2012 Resolves issue with setpoint return on scheduled events when entering HEAT/COOL/AUTO mode. 7.0.1 November 7 2012 Enables scheduling support 7.0.0 Supports Auto Update. Driver Version STRING true Automatic Updates LIST Off On Off false Control4 MAC Address STRING false Driver Information STRING true Debug Mode LIST Off On Off false CoolLink Firmware STRING true Decimal Separator LIST . , . false Get Firmware Version Get Firmware Version Send C4 settings to zone Send Set to FAN mode Set CoolLink NAME to FAN mode Set to DRY mode Set CoolLink NAME to DRY mode Set Fan Speed Set Fan Speed on NAME to PARAM1 Speed LIST Low Medium High Auto Top control4_thermostat_proxy 1 1 Serial RS-232 True True RS_232 5001 6 THERMOSTAT 2 False False False False THERMOSTAT 7000 6 Room Selection 7 False False False False False TEMPERATURE False TEMPERATURE_CONTROL True True False False 41 95 41 95 50 350 50 350 False Off,Heat,Cool Auto,High,Medium,Low Off,Heat,Cool False False False False False True False False False 9600 8 none 1 none