Copyright 2016 Control4 Corporation. All Rights Reserved.LuxomTemperature SensorTemperature SensorControl403/29/2011 10:3003/09/2016 12:00801lua_genDriverWorkstrue8002.9.0
Copyright 2016 Control4 corporation. All Rights Reserved.
8.0.1
CONTROL4 DRIVER FOR A LUXOM TEMPERATURE SENSOR
This driver enables Control4 to read the value of a Luxom temperature sensor.
A Control4 variable is provided to hold the current temperature value. You can choose the scale for this reading.
You can also set a High and Low warning level for the temperature. If the temperature falls outside those levels then a contact closure connection on the driver will close. You can then use that in Custom programming or to represent the warning on a Control4 UI.
----------------------------------
BRIEF INSTRUCTIONS
- Type the Luxom group into the Properties page
- Select the address for the Temperature sensor.
- Set the scale you require for the temperature.
- Ensure this driver is connected to the Luxom master driver on the Connections page.
- If you want to monitor for high and low temperatures then set these levels on the Properties page
- Connect the contact closure connections to appropriate Control4 elements.
----------------------------------
FULL INSTRUCTIONS
Full instructions for this driver are available on the dealer portal.
----------------------------------
SUPPORT
For support on this driver please contact Control4 technical support or your local Control4 distributor.
----------------------------------
AUTO UPDATE
This driver supports Auto Update. To enable this feature select Automatic Updates to 'On' on the Properties page of the master XXXX driver.
----------------------------------
CHANGELOG
8.0.1
Blinds driver now post OS2.9 Compliant
8.0.0 Sep 10 2014
Activation key removed
7.0.1 - 18 June 2014
Supports Advanced Lighting Scene tracking
7.0.0 September 28 2012
Initial release.
Driver Version
STRING
true
Debug Mode
LIST
- Off
- On
Off
false
Driver Information
STRING
true
Group
STRING
0
false
Address
STRING
1
false
High Temperature Warning Level
RANGED_INTEGER
-20
130
100
false
Low Temperature Warning Level
RANGED_INTEGER
-20
130
32
false
Temperature Scale
LIST
- F
- C
C
false
Current Temperature
STRING
true
RESET
RESET Min and Max Levels in NAME
true
ExtraVeg_Luxom_Temperature_Sensor
1
6
Luxom Circuit
1
True
False
False
True
Luxom_CIRCUIT
True
2
6
High Temperature Level Sensor
1
False
False
False
False
CONTACT_SENSOR
3
6
Low Temperature Level Sensor
1
False
False
False
False
CONTACT_SENSOR