Certified Copyright 2013 Control4 Corporation. All rights reserved. Control4 Middle Atlantic RLNK-SW715R [Network, Serial] RLNK-SW715R 06/11/2013 4:09 PM 06/11/2013 4:09 PM 1 devices_sm\c4.gif devices_lg\c4.gif lua_gen serial DriverWorks True others Middle Atlantic RLNK-SW815R-SP 1 6 Serial 232 1 True False False True RS_232 6001 6 Network Connection 4 True False False True TCP 60000 True True True AlwaysOn 0 0 False 9600 8 none 1 none 232 Control4 certified on 8/2/2013 for software released versions: 2.3, 2.5.0. Control4 certified on 6/25/2013 for software released versions: 2.4.0 2.5.0 Middle Atlantic RLNK-SW815R-SPRLNK-SW715R This driver supports both RS232 Serial and IP control For Serial you will need a female to female null modem cable. It utilizes pins 2, 3, and 5. Pins 2 and 3 should be reversed to make it null. For IP Ethernet control the default IP is 192.168.1.200 we utilize port 60000 which is the Control Protocol port. We recommend setting up a static address outside of the DHCP range We also recommend using the set up disk to connect to the device and make needed setup changes. We support Outlet On and Off, sequences and 3 controllable dry contacts located on the back of the device. The properties page of the driver allows you to enter a password that must match the one used on the Web interface in the User section. The default Username and Password are user and password. You can only change the password not the username. This driver also supports the temperature sensor that provides the ability to do greater than, less than or equal to a specific temperature as an event. Display Globals DisplayGlobals Outlet On Turn NAME Outlet PARAM1 On Outlet Number RANGED_INTEGER False 2 7 Outlet Off Turn Name Outlet PARAM1 Off Outlet Number RANGED_INTEGER False 3 7 Outlet Cycle Cycle Name Outlet PARAM1 over PARAM2 seconds Outlet Number RANGED_INTEGER False 3 7 Cycle Time RANGED_INTEGER False 3 0 3600 Contact On Turn Name Contact PARAM1 On Contact Number RANGED_INTEGER False 1 4 Contact Off Turn Name Contact PARAM1 Off Contact Number RANGED_INTEGER False 1 4 Contact Cycle Cycle Name Contact PARAM1 over PARAM2 seconds Contact Number RANGED_INTEGER False 1 4 Cycle Time RANGED_INTEGER False 3 0 3600 Sequence Outlets Up Sequence NAME power outlets on over PARAM1 seconds Delay Time RANGED_INTEGER False 0 9999 Sequence Outlets Down Sequence NAME power outlets off over PARAM1 seconds Delay Time RANGED_INTEGER False 0 9999 Debug Level LIST false 2 - Warning 0 - Alert 1 - Error 2 - Warning 3 - Info 4 - Trace 5 - Debug Debug Mode LIST false Off Off Print Log Print and Log Password STRING false true password 3 Outlet 3 On When NAME outlet 3 turns on 4 Outlet 4 On When NAME outlet 4 turns on 5 Outlet 5 On When NAME outlet 5 turns on 6 Outlet 6 On When NAME outlet 6 turns on 7 Outlet 7 On When NAME outlet 7 turns on 11 Outlet 3 Off When NAME outlet 3 turns off 12 Outlet 4 Off When NAME outlet 4 turns off 13 Outlet 5 Off When NAME outlet 5 turns off 14 Outlet 6 Off When NAME outlet 6 turns off 15 Outlet 7 Off When NAME outlet 7 turns off 17 Contact 1 On When NAME contact 1 turns on 18 Contact 2 On When NAME contact 2 turns on 19 Contact 3 On When NAME contact 3 turns on 20 Contact 1 Off When NAME contact 1 turns off 21 Contact 2 Off When NAME contact 2 turns off 22 Contact 3 Off When NAME contact 3 turns off 23 Sequence Outlet Up When NAME Sequence Outlet Up starts 24 Sequence Outlet Up Complete When NAME Sequence Outlet Up completes 25 Sequence Outlet Down When NAME Sequence Outlet Down starts 26 Sequence Outlet Down Complete When NAME Sequence Outlet Down completes 27 Current Temperature When NAME current temperature changes 8 Contact 4 On When NAME contact 4 turns on 9 Contact 4 Off When NAME contact 4 turns off Control4 certified on 8/2/2013 for software released versions: 2.3, 2.5.0.