Control4 certified on 8/18/2014 for software released versions: 2.5.3
B-500 HDMATRIX IP CONFIGURATION:
Set HDMATRIX Network settings:
1) Connect the HDMATRIX to the network via RJ45/CAT5 and to your computer via straight-through DB9/RS232 cable.
2) Run the HDMATRIX Configuration Utility software for your model of HDMATRIX.
3) Select the appropriate RS232 COM port and click on "Connect".
4) When connected click on "Network Configuration".
5) In the Device Setting window:
- Enter a static IP address for the HDMATRIX;
- Enter a network Mask of 255.255.255.0;
- Enter zeros ("0") in all fields for Gateway, DNS1 and DNS2 (e.g., "0.0.0.0");
- Click on "Write To Device";
- Wait 15 seconds, then click on "Read From Device";
- Verify the settings.
- If settings are not correct, repeat this entire step.
- If settings are correct, click on the Close widget in the upper right corner of the Device Setting window.
6) Disconnect the DB9/RS232 connection to the computer.
COMPOSER CONFIGURATION:
Enter IP Address of the receiver into Composer:
1) In the Composer/Items/Discovered column tab, double click the Binary B-500 HDMATRIX switch.
2) The driver will automatically be installed and should self configure..
3) Do NOT edit the IP Port, Username or Password fields.
4) Verify the HDMATRIX is connected to Director by reviewing the Composer/Properties/Properties tab "Driver Information" field.
- When properly configured and connected it should read "Switch found, firmware: " and the installed firmware version of the HDMATRIX.
CONTROL AND AUDIO/VIDEO CONNECTIONS:
1) In the Composer/Connections/ Control/AV tab, select the HDMATRIX and make all appropriate Input and Output connections.
Driver Information
STRING
true
Debug Mode
LIST
- Off
- On
Off
false
Allow Power Off
LIST
- Yes
- No
No
false
Allow Output Disconnects
LIST
- Yes
- No
No
false
IP Address
STRING
true
IP Port
RANGED_INTEGER
1
65535
23
false
Username
STRING
admin
false
Password
STRING
123
false
NEXT_INPUT
Select next input on PARAM1 on NAME
OUTPUT
RANGED_INTEGER
1
16
PREV_INPUT
Select previous input on PARAM1 on NAME
OUTPUT
RANGED_INTEGER
1
16
avswitch
5001
2
AV Switch
False
True
AVSWITCH
6001
1
Ethernet
4
True
False
False
True
TCP
23
True
True
False
2000
5
Output 1
False
True
HDMI
2001
5
Output 2
False
True
HDMI
2002
5
Output 3
False
True
HDMI
2003
5
Output 4
False
True
HDMI
2004
5
Output 5
False
True
HDMI
2005
5
Output 6
False
True
HDMI
2006
5
Output 7
False
True
HDMI
2007
5
Output 8
False
True
HDMI
2008
5
Output 9
False
True
HDMI
2009
5
Output 10
False
True
HDMI
2010
5
Output 11
False
True
HDMI
2011
5
Output 12
False
True
HDMI
2012
5
Output 13
False
True
HDMI
2013
5
Output 14
False
True
HDMI
2014
5
Output 15
False
True
HDMI
2015
5
Output 16
False
True
HDMI
1000
5
Input 1
True
True
HDMI
1001
5
Input 2
True
True
HDMI
1002
5
Input 3
True
True
HDMI
1003
5
Input 4
True
True
HDMI
1004
5
Input 5
True
True
HDMI
1005
5
Input 6
True
True
HDMI
1006
5
Input 7
True
True
HDMI
1007
5
Input 8
True
True
HDMI
1008
5
Input 9
True
True
HDMI
1009
5
Input 10
True
True
HDMI
1010
5
Input 11
True
True
HDMI
1011
5
Input 12
True
True
HDMI
1012
5
Input 13
True
True
HDMI
1013
5
Input 14
True
True
HDMI
1014
5
Input 15
True
True
HDMI
1015
5
Input 16
True
True
HDMI
0
0
False
True
False
False
True
False
True
16
16
True
False
ip
binary:avswitch