Certified Copyright Extra Vegetables LTD. All rights reserved. BINARY Binary B-500 HDMATRIX 16x16 (IP) Binary B-500-MTRX-230-16x16 (IP) Extra Vegetables 09/12/2013 10:30 08/08/2014 11:00 200 lua_gen DriverWorks Copyright Extra Vegetables LTD. All rights reserved. 2.0.0 Control4 certified on 8/18/2014 for software released versions: 2.5.3 B-500 HDMATRIX IP CONFIGURATION: Set HDMATRIX Network settings: 1) Connect the HDMATRIX to the network via RJ45/CAT5 and to your computer via straight-through DB9/RS232 cable. 2) Run the HDMATRIX Configuration Utility software for your model of HDMATRIX. 3) Select the appropriate RS232 COM port and click on "Connect". 4) When connected click on "Network Configuration". 5) In the Device Setting window: - Enter a static IP address for the HDMATRIX; - Enter a network Mask of 255.255.255.0; - Enter zeros ("0") in all fields for Gateway, DNS1 and DNS2 (e.g., "0.0.0.0"); - Click on "Write To Device"; - Wait 15 seconds, then click on "Read From Device"; - Verify the settings. - If settings are not correct, repeat this entire step. - If settings are correct, click on the Close widget in the upper right corner of the Device Setting window. 6) Disconnect the DB9/RS232 connection to the computer. COMPOSER CONFIGURATION: Enter IP Address of the receiver into Composer: 1) In the Composer/Items/Discovered column tab, double click the Binary B-500 HDMATRIX switch. 2) The driver will automatically be installed and should self configure.. 3) Do NOT edit the IP Port, Username or Password fields. 4) Verify the HDMATRIX is connected to Director by reviewing the Composer/Properties/Properties tab "Driver Information" field. - When properly configured and connected it should read "Switch found, firmware: " and the installed firmware version of the HDMATRIX. CONTROL AND AUDIO/VIDEO CONNECTIONS: 1) In the Composer/Connections/ Control/AV tab, select the HDMATRIX and make all appropriate Input and Output connections. Driver Information STRING true Debug Mode LIST Off On Off false Allow Power Off LIST Yes No No false Allow Output Disconnects LIST Yes No No false IP Address STRING true IP Port RANGED_INTEGER 1 65535 23 false Username STRING admin false Password STRING 123 false NEXT_INPUT Select next input on PARAM1 on NAME OUTPUT RANGED_INTEGER 1 16 PREV_INPUT Select previous input on PARAM1 on NAME OUTPUT RANGED_INTEGER 1 16 avswitch 5001 2 AV Switch False True AVSWITCH 6001 1 Ethernet 4 True False False True TCP 23 True True False 2000 5 Output 1 False True HDMI 2001 5 Output 2 False True HDMI 2002 5 Output 3 False True HDMI 2003 5 Output 4 False True HDMI 2004 5 Output 5 False True HDMI 2005 5 Output 6 False True HDMI 2006 5 Output 7 False True HDMI 2007 5 Output 8 False True HDMI 2008 5 Output 9 False True HDMI 2009 5 Output 10 False True HDMI 2010 5 Output 11 False True HDMI 2011 5 Output 12 False True HDMI 2012 5 Output 13 False True HDMI 2013 5 Output 14 False True HDMI 2014 5 Output 15 False True HDMI 2015 5 Output 16 False True HDMI 1000 5 Input 1 True True HDMI 1001 5 Input 2 True True HDMI 1002 5 Input 3 True True HDMI 1003 5 Input 4 True True HDMI 1004 5 Input 5 True True HDMI 1005 5 Input 6 True True HDMI 1006 5 Input 7 True True HDMI 1007 5 Input 8 True True HDMI 1008 5 Input 9 True True HDMI 1009 5 Input 10 True True HDMI 1010 5 Input 11 True True HDMI 1011 5 Input 12 True True HDMI 1012 5 Input 13 True True HDMI 1013 5 Input 14 True True HDMI 1014 5 Input 15 True True HDMI 1015 5 Input 16 True True HDMI 0 0 False True False False True False True 16 16 True False ip binary:avswitch Control4 certified on 8/18/2014 for software released versions: 2.5.3