Certified
Copyright 2015 SnapAV. All rights reserved.
Kris Brant
BINARY
Binary B-520-MTRX-230-4x4 [IP]
Binary B-520-MTRX-230-4x4 [IP]
01/15/2015 9:20 AM
01/15/2015 9:20 AM
202
lua_gen
ip
DriverWorks
binary:avswitch
avswitch
0
0
False
True
False
False
True
False
True
4
4
True
False
1000
6
Input 1
5
True
False
False
True
HDMI
1001
6
Input 2
5
True
False
False
True
HDMI
1002
6
Input 3
5
True
False
False
True
HDMI
1003
6
Input 4
5
True
False
False
True
HDMI
2000
6
Output 1
5
False
False
False
True
HDMI
2001
6
Output 2
5
False
False
False
True
HDMI
2002
6
Output 3
5
False
False
False
True
HDMI
2003
6
Output 4
5
False
False
False
True
HDMI
5001
6
BINARY B-520-MTRX-230-4X4
2
False
False
False
True
AVSWITCH
6001
1
Ethernet
4
True
False
False
True
TCP
23
True
True
Copyright 2014 Control4 Corporation. All rights reserved.
2.0.1
AlwaysOn
0
0
False
Control4 certified on 10/21/2015 for software released versions: 2.8.2
B-520-MTRX-230-4X4 IP CONFIGURATION:
Set HDMATRIX Network settings:
1) Connect the B-520-MTRX-230-4X4 to the network via RJ45/CAT5 and to your computer via straight-through DB9/RS232 cable.
2) Run the B-520-MTRX-230-4X4 Configuration Utility software for your model of HDMATRIX.
3) Select the appropriate RS232 COM port and click on "Connect".
4) When connected click on "Network Configuration".
5) In the Device Setting window:
- Enter a static IP address for the B-520-MTRX-230-4X4;
- Enter a network Mask of 255.255.255.0;
- Enter zeros ("0") in all fields for Gateway, DNS1 and DNS2 (e.g., "0.0.0.0");
- Click on "Write To Device";
- Wait 15 seconds, then click on "Read From Device";
- Verify the settings.
- If settings are not correct, repeat this entire step.
- If settings are correct, click on the Close widget in the upper right corner of the Device Setting window.
6) Disconnect the DB9/RS232 connection to the computer.
COMPOSER CONFIGURATION:
Enter IP Address of the receiver into Composer:
1) In the Composer/Items/Discovered column tab, double click the Binary B-500 HDMATRIX switch.
2) The driver will automatically be installed and should self configure..
3) Do NOT edit the IP Port, Username or Password fields.
4) Verify the B-520-MTRX-230-4X4 is connected to Director by reviewing the Composer/Properties/Properties tab "Driver Information" field.
- When properly configured and connected it should read "Switch found, firmware: " and the installed firmware version of the B-520-MTRX-230-4X4.
CONTROL AND AUDIO/VIDEO CONNECTIONS:
1) In the Composer/Connections/ Control/AV tab, select the B-520-MTRX-230-4X4 and make all appropriate Input and Output connections.
NEXT_INPUT
Select next input on PARAM1 on NAME
OUTPUT
RANGED_INTEGER
False
1
4
PREV_INPUT
Select previous input on PARAM1 on NAME
OUTPUT
RANGED_INTEGER
False
1
4
Driver Information
STRING
true
Debug Mode
LIST
false
Off
- Off
- On
Allow Power Off
LIST
false
No
- Yes
- No
Allow Output Disconnects
LIST
false
No
- Yes
- No
IP Address
STRING
true
IP Port
RANGED_INTEGER
false
23
1
65535
Username
STRING
false
admin
Password
STRING
false
123
Control4 certified on 10/21/2015 for software released versions: 2.8.2