Certified Copyright 2015 SnapAV. All rights reserved. Kris Brant BINARY Binary B-520-MTRX-230-4x4 [IP] Binary B-520-MTRX-230-4x4 [IP] 01/15/2015 9:20 AM 01/15/2015 9:20 AM 202 lua_gen ip DriverWorks binary:avswitch avswitch 0 0 False True False False True False True 4 4 True False 1000 6 Input 1 5 True False False True HDMI 1001 6 Input 2 5 True False False True HDMI 1002 6 Input 3 5 True False False True HDMI 1003 6 Input 4 5 True False False True HDMI 2000 6 Output 1 5 False False False True HDMI 2001 6 Output 2 5 False False False True HDMI 2002 6 Output 3 5 False False False True HDMI 2003 6 Output 4 5 False False False True HDMI 5001 6 BINARY B-520-MTRX-230-4X4 2 False False False True AVSWITCH 6001 1 Ethernet 4 True False False True TCP 23 True True Copyright 2014 Control4 Corporation. All rights reserved. 2.0.1 AlwaysOn 0 0 False Control4 certified on 10/21/2015 for software released versions: 2.8.2 B-520-MTRX-230-4X4 IP CONFIGURATION: Set HDMATRIX Network settings: 1) Connect the B-520-MTRX-230-4X4 to the network via RJ45/CAT5 and to your computer via straight-through DB9/RS232 cable. 2) Run the B-520-MTRX-230-4X4 Configuration Utility software for your model of HDMATRIX. 3) Select the appropriate RS232 COM port and click on "Connect". 4) When connected click on "Network Configuration". 5) In the Device Setting window: - Enter a static IP address for the B-520-MTRX-230-4X4; - Enter a network Mask of 255.255.255.0; - Enter zeros ("0") in all fields for Gateway, DNS1 and DNS2 (e.g., "0.0.0.0"); - Click on "Write To Device"; - Wait 15 seconds, then click on "Read From Device"; - Verify the settings. - If settings are not correct, repeat this entire step. - If settings are correct, click on the Close widget in the upper right corner of the Device Setting window. 6) Disconnect the DB9/RS232 connection to the computer. COMPOSER CONFIGURATION: Enter IP Address of the receiver into Composer: 1) In the Composer/Items/Discovered column tab, double click the Binary B-500 HDMATRIX switch. 2) The driver will automatically be installed and should self configure.. 3) Do NOT edit the IP Port, Username or Password fields. 4) Verify the B-520-MTRX-230-4X4 is connected to Director by reviewing the Composer/Properties/Properties tab "Driver Information" field. - When properly configured and connected it should read "Switch found, firmware: " and the installed firmware version of the B-520-MTRX-230-4X4. CONTROL AND AUDIO/VIDEO CONNECTIONS: 1) In the Composer/Connections/ Control/AV tab, select the B-520-MTRX-230-4X4 and make all appropriate Input and Output connections. NEXT_INPUT Select next input on PARAM1 on NAME OUTPUT RANGED_INTEGER False 1 4 PREV_INPUT Select previous input on PARAM1 on NAME OUTPUT RANGED_INTEGER False 1 4 Driver Information STRING true Debug Mode LIST false Off Off On Allow Power Off LIST false No Yes No Allow Output Disconnects LIST false No Yes No IP Address STRING true IP Port RANGED_INTEGER false 23 1 65535 Username STRING false admin Password STRING false 123 Control4 certified on 10/21/2015 for software released versions: 2.8.2