Copyright 2004-2013 Control4 Corporation. All rights reserved.
Control4 (support@control4.com)
Kramer
Kramer VS-88HDXL (Serial)
VS-88HDXL
03/13/2014 11:33 AM
09/15/2014 04:35 PM
2
devices_sm\receiver.gif
devices_lg\receiver.gif
lua_gen
serial
DriverWorks
c4:av_gen
avswitch
0
0
False
True
True
False
False
False
False
True
False
False
False
False
False
False
False
False
False
False
False
False
True
8
8
True
True
1
1
RS-232
1
True
False
False
True
RS_232
1001
1
Input 1
5
True
False
False
False
COMPOSITE
1002
1
Input 2
5
True
False
False
False
COMPOSITE
1003
1
Input 3
5
True
False
False
True
COMPOSITE
1004
1
Input 4
5
True
False
False
True
COMPOSITE
1005
1
Input 5
5
True
False
False
True
COMPOSITE
1006
1
Input 6
5
True
False
False
False
COMPOSITE
1007
1
Input 7
5
True
False
True
False
COMPOSITE
1008
1
Input 8
5
True
False
False
False
COMPOSITE
2001
1
Output 1
5
False
False
False
False
COMPOSITE
2002
1
Output 2
5
False
False
False
False
COMPOSITE
2003
1
Output 3
5
False
False
False
False
COMPOSITE
2004
1
Output 4
5
False
False
False
False
COMPOSITE
2005
1
Output 5
5
False
False
False
False
COMPOSITE
2006
1
Output 6
5
False
False
False
False
COMPOSITE
2007
1
Output 7
5
False
False
False
False
COMPOSITE
2008
1
Output 8
5
False
False
False
False
COMPOSITE
5001
6
AV SWITCH
2
False
False
False
False
AVSWITCH
6000
1
Network
4
True
False
False
True
TCP
5000
True
True
True
7001
6
Room Selection - Zone1 Output
7
False
False
False
True
VIDEO_SELECTION
7002
6
Room Selection - Zone2 Output
7
False
False
False
True
VIDEO_SELECTION
7003
6
Room Selection - Zone3 Output
7
False
False
False
True
VIDEO_SELECTION
7004
6
Room Selection - Zone4 Output
7
False
False
False
True
VIDEO_SELECTION
7005
6
Room Selection - Zone5 Output
7
False
False
False
True
VIDEO_SELECTION
7006
6
Room Selection - Zone6 Output
7
False
False
False
True
VIDEO_SELECTION
7007
6
Room Selection - Zone7 Output
7
False
False
False
True
VIDEO_SELECTION
7008
6
Room Selection - Zone8 Output
7
False
False
False
True
VIDEO_SELECTION
AlwaysOn
0
0
False
115200 8 none 1 none 232
Kramer VS-88HDXL Created on 3/13/2014
CONTENTS
========
General Notes
Control Methods
Hardware Setup
Timer Delay Property Settings
Release Notes
GENERAL NOTES
==================
The hardware supports both of Kramer's protocols 2000 and 3000. This driver is written using the 3000 protocol in ASCII format. Press output buttons 1 and 3 at the same time to put the unit in 3000 mode.
CONTROL METHODS
==============
This driver supports Network and Serial. When more than one control binding is made the driver will automatically select the active control binding in this priority order:
-Network
-Serial
HARDWARE SETUP
==============
To Control with serial use a straight through serial cable.
Baud Rate 115220
Data Bit 8
Parity None
Stop Bit 1
Flow Control None
To Control with IP set the unit to a static IP address outside the DHCP range. Please see the user documentation from Kramer to set the IP address.
IP PORT 5000 is the factory default port, this is what the driver is set to. To reset the IP port press and hold the factory reset button on the back of the unit while turning the unit on.
TIMER DELAY PROPERTY SETTINGS
===============
A command timer marshals commands using the "Command Delay Milliseconds" to set the timer interval.
The Command Delay Milliseconds value is simply the time elapsed between each command that is sent to the Anthem MRX processors.
There is also a "Power On Delay Seconds" used to establish the amount of time that will elapse during the power-on sequence before the driver continues to issue commands.
When using the Network Control Method, the "Polling Interval Seconds" value determines how often the driver will send a keep-alive query to the receiver. This query is useful in testing and maintaining a network connection.
RELEASE NOTES
=============
This driver was modeled after the protocol 3000 documentation and tested on a device that supports the protocol 3000. If there are issues with this driver please contact support.
Debug Mode
LIST
false
Off
- Off
- Print
- Log
- Print and Log
Debug Level
LIST
false
2 - Warning
- 0 - Alert
- 1 - Error
- 2 - Warning
- 3 - Info
- 4 - Trace
- 5 - Debug
Volume Ramp Delay Milliseconds
RANGED_INTEGER
false
150
50
500
Command Delay Milliseconds
RANGED_INTEGER
false
500
50
2500