Copyright 2016 Control4. All rights reserved. Lutron 4 Control4 03/24/2016 08:00 PM 05/10/2018 5:00 PM RadioRA 2 Sivoia QS Triathlon Roller Shade Motorization Comfort devices_sm/blinds.gif devices_lg/blinds.gif Lutron RadioRA 2 Sivoia QS Triathlon Roller Shade lua_gen blind DriverWorks Lutron RadioRA 2 Sivoia QS Triathlon Roller Shade Driver Set Version: [v2 rev20161229] ------------------------------------------------------------------------------------------- ONLINE DOCUMENTATION ------------------------------------------------------------------------------------------- Online Support: https://www.lutron.com/ Technical Support: 1.800.523.9466 (24 hours a day / 7 days a week) ------------------------------------------------------------------------------------------- OVERVIEW ------------------------------------------------------------------------------------------- When installing drivers to connect to a Lutron RadioRA2 system, it is recommended that you add the Lutron RadioRA2 Network driver first. RadioRA2 Network is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers, then the other drivers will be automatically connected to the RadioRA2 Network driver. If that driver is not added first, then those connections will need to be made manually. This driver REQUIRES version 27 or greater of the RadioRA 2 repeater driver. The RadioRA2 Shade driver is used to control and monitor shades on the Lutron RadioRA2 system. When the driver is added it is automatically linked to a RadioRA2 Network driver if it exists. If the driver does not exist the connection will need to be made manually after it has been added. Known Issues 1. Pressing a ramp button on a Lutron remote/keypad that is the same direction as the blind's current movement will stop the shade but report an incorrect level. However pressing a ramp button in the opposite direction of the current movement will stop the blind and report the correct level. 2. There is no way to get a reliable value for the shade level on director startup. The shade will start with an unknown value until it is moved either by the Control4 system or by using a Lutron remote/keypad. 3. The Lutron system does not support stop commands when moving to a discrete level. Toggle commands are dependent on stop so toggle is also suspended when moving to a discrete level. Stop is only supported when moving to the full open/close level. Properties Device Address: This is the integration ID or address of the shade. Debug Mode: Used for debugging the driver. Output is displayed on the Lua tab. Options: Off Print Log Print and Log Ramp Time (Seconds): This is the time in seconds that it takes the shade to go from a fully open to a fully closed position. To Be Determined. Device Address STRING false Debug Mode LIST Off Print Log Print and Log Off false Ramp Time (Seconds) RANGED_INTEGER false 10 1 1800 Delay Shade Delay shade level on NAME to PARAM1, Delay Time = PARAM2 : PARAM3 : PARAM4 Level RANGED_INTEGER 0 100 Delay Hours RANGED_INTEGER 0 99 Delay Minutes RANGED_INTEGER 0 59 Delay Seconds RANGED_INTEGER 0 59 1 6 Lutron RadioRA2 Control 1 True False False True LUTRON_RA2_SHADE True 5001 6 Blinds 2 False False False False BLIND True True 1 0 100 True