Copyright 2016 Control4. All rights reserved.
Lutron
4
Control4
03/24/2016 08:00 PM
05/10/2018 5:00 PM
RadioRA 2 Sivoia QS Triathlon Roller Shade
Motorization
Comfort
devices_sm/blinds.gif
devices_lg/blinds.gif
Lutron RadioRA 2 Sivoia QS Triathlon Roller Shade
lua_gen
blind
DriverWorks
Lutron RadioRA 2 Sivoia QS Triathlon Roller Shade
Driver Set Version: [v2 rev20161229]
-------------------------------------------------------------------------------------------
ONLINE DOCUMENTATION
-------------------------------------------------------------------------------------------
Online Support: https://www.lutron.com/
Technical Support: 1.800.523.9466 (24 hours a day / 7 days a week)
-------------------------------------------------------------------------------------------
OVERVIEW
-------------------------------------------------------------------------------------------
When installing drivers to connect to a Lutron RadioRA2 system, it is recommended that you add the Lutron RadioRA2 Network driver first.
RadioRA2 Network is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers,
then the other drivers will be automatically connected to the RadioRA2 Network driver. If that driver is not added first, then those connections
will need to be made manually.
This driver REQUIRES version 27 or greater of the RadioRA 2 repeater driver.
The RadioRA2 Shade driver is used to control and monitor shades on the Lutron RadioRA2 system. When the driver is added it is automatically linked
to a RadioRA2 Network driver if it exists. If the driver does not exist the connection will need to be made manually after it has been added.
Known Issues
1. Pressing a ramp button on a Lutron remote/keypad that is the same direction as the blind's current movement will stop the shade but report an
incorrect level. However pressing a ramp button in the opposite direction of the current movement will stop the blind and report the correct level.
2. There is no way to get a reliable value for the shade level on director startup. The shade will start with an unknown value until it is moved
either by the Control4 system or by using a Lutron remote/keypad.
3. The Lutron system does not support stop commands when moving to a discrete level. Toggle commands are dependent on stop so toggle is also
suspended when moving to a discrete level. Stop is only supported when moving to the full open/close level.
Properties
Device Address:
This is the integration ID or address of the shade.
Debug Mode:
Used for debugging the driver. Output is displayed on the Lua tab.
Options:
Off
Print
Log
Print and Log
Ramp Time (Seconds):
This is the time in seconds that it takes the shade to go from a fully open to a fully closed position.
To Be Determined.
Device Address
STRING
false
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Ramp Time (Seconds)
RANGED_INTEGER
false
10
1
1800
Delay Shade
Delay shade level on NAME to PARAM1, Delay Time = PARAM2 : PARAM3 : PARAM4
Level
RANGED_INTEGER
0
100
Delay Hours
RANGED_INTEGER
0
99
Delay Minutes
RANGED_INTEGER
0
59
Delay Seconds
RANGED_INTEGER
0
59
1
6
Lutron RadioRA2 Control
1
True
False
False
True
LUTRON_RA2_SHADE
True
5001
6
Blinds
2
False
False
False
False
BLIND
True
True
1
0
100
True