BPL IQ 3Button Keypad
BPL IQ 3Button Keypad
bpl_iq_3button_keypad
true
DriverWorks
lua_gen
others
Sensors
User Interface
devices_sm/ThreeButtonKeypad.gif
devices_lg/ThreeButtonKeypad.gif
1
Switch1 Pressed
Switch1 is Pressed
2
Switch2 Pressed
Switch2 is Pressed
3
Switch3 Pressed
Switch3 is Pressed
4
Battery Low
On NAME Battery Low
BPL IQ 3Button Keypad driver
Prerequisite:
1. Check for the led on gateway device, to confirm the connection with Control4 system is up.
Adding BPL 3Button Keypad device
Go to System Design, search Device type:--others-- and Manufacturer:BPL.
Configuration
On the properties page of the BPL 3Button Keypad driver,
1. IEEE : Enter the IEEE number of the device.
Adding the BPL 3Button Keypad device to Network
1. On the Actions page of gateway driver, click on Permit Join button.
[This opens a 60 seconds window on the gateway, for devices to join.]
2. Press and Factory button on the device and insert the batteries. Factory reset on the device is
indicated by the led flashing rapidly. Power cycle the device(remove and insert the batteries in)
On successfull join, the properties page of the BPL 3Button Keypad will indicate the Network status
as "Online".And the led on the device will be on.
Binding the Switches
1. Bind switch1 : On the actions page, press button 'Bind Switch1'. On the device press the button once.
'Switch1 Bind Status' on the properties page will indicate 'Bind Success' or 'Bind Failure'.
2. Bind switch2 : On the actions page, press button 'Bind Switch2'. On the device press the button twice.
'Switch2 Bind Status' on the properties page will indicate 'Bind Success' or 'Bind Failure'.
3. Bind switch3 : On the actions page, press button 'Bind Switch3'. On the device press the button once.
'Switch3 Bind Status' on the properties page will indicate 'Bind Success' or 'Bind Failure'.
For Technical Support, please contact:
Email : Support.BPLIQ@bpl.in
Phone : +91 80 32719381
Set IEEE
STRING
00137A0000005427
false
DB Status
STRING
Device not present
true
Network Status
STRING
Offline
true
Battery Status
STRING
Ok
true
Switch1 Bind Status
STRING
Not Bound
true
Switch2 Bind Status
STRING
Not Bound
true
Switch3 Bind Status
STRING
Not Bound
true
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Bind Switch3
SWITCH3_BIND
Bind Switch2
SWITCH2_BIND
Bind Switch1
SWITCH1_BIND
1
6
BPL IQ Proxy
1
True
False
False
True
BPL_PROXY
True