Certified7056SharpLC-60LE925UN [Serial][DriverWorks]c4:av_genControl4Sharp LC-60LE925UNdevices_sm\tv.gifdevices_lg\tv.giflua_genDriverWorksCopyright 2004-2007 Control4 Corporation. All rights reserved.8/12/2010 3:24:07 PM10/18/2011 9:23:01 AMtvtvTrueTrueTrueTrueTrueTrueTrueTrue0814TrueTrue50016TV2FalseFalseFalseFalseTV16Serial1TrueFalseFalseTrueRS_23240006Output6FalseTrueFalseTrueDIGITAL_OPTICALSTEREO70006Room Selection - Output7FalseTrueTrueTrueAUDIO_SELECTIONAUDIO_VOLUMEVIDEO_SELECTION10016CABLE/TV5TrueFalseFalseTrueRF_CABLERF_UHF_VHF30026COMPONENT6TrueFalseFalseTrueSTEREO10026COMPONENT5TrueFalseFalseTrueCOMPONENT30036HDMI 16TrueFalseFalseTrueSTEREO10036HDMI 15TrueFalseFalseTrueHDMI10046HDMI 25TrueFalseFalseTrueHDMI10056HDMI 35TrueFalseFalseTrueHDMI10066HDMI 45TrueFalseFalseTrueHDMI30076PC IN6TrueFalseFalseTrueSTEREO10076PC IN5TrueFalseFalseTrueVGA30086VIDEO6TrueFalseFalseTrueSTEREO10086VIDEO5TrueFalseFalseTrueCOMPOSITEControl4 certified on 2/16/2011 for software released versions: 1.8.2, 2.0.6. POWER ON COMMAND SETTING: IMPORTANT NOTE - By default the TV will reject the Power On command. During installation, the TV must be turned on manually and then, using the Actions Tab, sent the appropriate ENABLE POWER_ON command. Via the Actions Tab, the TV can be configured to Accept or Reject the Power On Command. -ENABLE POWER_ON_RS232 will configure the TV to Accept the Power On Command when controlling via RS-232. -ENABLE POWER_ON_IP will configure the TV to Accept the Power On Command when controlling via IP. -DISABLE POWER_ON will configure the TV to Reject the Power On Command. RS-232 CABLE SPEC: RS-232C straight cable. PROPERTIES: -Command Delay-Milliseconds. Typically this is the amountof time that the driver will wait to send a Command after a previous Command has been sent. This is Property is not used in this driver since a Command will not be send after a previous Command until a Response is received from te TV. -Response Wait Timer Delay-Seconds. In the event that no Response is received from the TV after a Command is sent, the driver will process subsequent Commands after the amount of time specified by this Property. -Volume Ramp Delay-Milliseconds. The amount of time between Volume Up or Volume Down Commands. -Channel Buffer Timer Value. When entering Digits from the Keypad for Channel Tuning, this is the amount of time after the first Digit is entered that it will take for the SET_CHANNEL command to be sent. -Power On Delay-Seconds. This is the Delay after a Power On Command is sent before a susequnet Command will be sent. -Polling Timer Delay - Seconds. A Polling Timer is implemented to periodically poll the TV for current status of power state, currently selected input, current volume and mute state. DEVICE SPECIFIC COMMANDS: The following commands are included in this driver for use by models that support these capabilities. These commands can be accessed via Programming or Custom Buttons: SLEEP CC AV_MODE VIEW_MODE AQUOSNet C_3DOFF C_2DTO3D C_SBS C_TAB C_3DTO2D C_3DTO2D_SBS C_3DTO2D_TAB C_AUTO POLLING TIMER: A Polling Timer is implemented to periodically poll the TV for current status of power state, currently selected input, currently selected channel, current volume and mute state. The polling interval is dictated by the "Polling Timer Delay" whcih can be set via the driver's "Properties" tab. TIP: If the Polling Timer is not running when the TV is On, then the Power Delay may need to be increased. COMMAND QUEUE: All commands are stacked in order in the command queue. Once a command is sent to the TV, the next command in the queue will not be sent until the first of either of the following occurs 1) and acknolwledgement is received from the TV 2) the amount of time delcared in the "Response Timeout" elapses The "Command Delay" and "Volume Ramp Delay" dictate how often the command queue is checked. When checked, the next command in the queue will be sent to the TV unless it is waiting for a response from a command sent previously. The "Power On Delay" dictates how long the driver will wait before sending the next command in the queue after the "ON" command is sent. The "Response Timeout", "Command Delay", "Volume Ramp Delay" and "Power On Delay" may be set via the driver's "Properties" tab. SLEEPSLEEPCCCCAV_MODEAV MODE TOGGLEVIEW_MODEVIEW MODE TOGGLEAQUOSNetAQUOSNetC_3DOFF3D OFFC_2DTO3D2D TO 3DC_SBS3D SBSC_TAB3D TABC_3DTO2D3D TO 2D (Return to previous mode)C_3DTO2D_SBS3D TO 2D (SBS)C_3DTO2D_TAB3D TO 2D (TAB)C_AUTO3D AUTOAPP1APP1APP2APP2APP3APP3Debug ModeLISTOffPrintLogPrint and LogOfffalseCommand Delay-MillisecondsRANGED_INTEGER502500250falseVolume Ramp Delay-MillisecondsRANGED_INTEGER50500250falseDirect Channel TuningLISTAnalogDigital AirDigital Cable - Two PartDigital Cable - One Part00Digital AirfalseChannel Buffer Timer ValueRANGED_INTEGER153falseResponse Wait Timer Delay-SecondsRANGED_INTEGER02510falsePower On Delay-SecondsRANGED_INTEGER02515falsePolling Timer Delay-SecondsRANGED_INTEGER1605falseENABLE POWER_ON_RS232ENABLE POWER_ON_RS232ENABLE POWER_ON_IPENABLE POWER_ON_IPDISABLE POWER_ONDISABLE POWER_ONDestroy All TimersDestroy TimersDiscreteCodes012Truerf_cablerf_uhf_vhf9600 8 none 1 none 232Control4 certified on 2/16/2011 for software released versions: 1.8.2, 2.0.6.serial