Copyright 2014 HouseLogix Corporation. All rights reserved.
Lutron
24
HouseLogix, Inc.
10/06/2009 10:00 PM
09/23/2014 12:00 PM
HomeWorksQS Dimmer
Lights
devices_sm/LutronDimmer.gif
devices_lg/LutronDimmer.gif
Lutron HomeWorksQS Dimmer
lua_gen
light_v2
DriverWorks
Lutron HomeWorksQS Dimmer
Driver Set Version: [v24 rev20151007]
-------------------------------------------------------------------------------------------
ONLINE DOCUMENTATION
-------------------------------------------------------------------------------------------
Online Support: https://www.lutron.com/
Technical Support: 1.800.523.9466 (24 hours a day / 7 days a week)
-------------------------------------------------------------------------------------------
OVERVIEW
-------------------------------------------------------------------------------------------
When installing drivers to connect to a Lutron HomeWorksQS system, it is recommended that you add the Lutron HomeWorksQS Processor driver first.
HomeWorksQS Processor is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers,
then the other drivers will be automatically connected to the HomeWorksQS Processor driver. If that driver is not added first, then those connections
will need to be made manually.
The HomeWorksQS Dimmer driver is used to control and monitor any dimmer on the Lutron HomeWorksQS system. One driver should be added for each load
that is controlled or monitored. When the driver is added it is automatically linked to a HomeWorksQS Processor driver if it exists. If the driver
does not exist the connection will need to be made manually after it has been added.
Properties
Device Address:
This is the integration ID or address of the dimmer.
Debug Mode:
Used for debugging the driver. Output is displayed on the Lua tab.
Options:
- Off
- Print
- Log
- Print and Log
Variables
Same as the C4 Light Proxy.
Events
Since the Lutron HomeWorksQS system dimmers only use one button, then the "Top Button" is used for events. * Please note that button press and
release events for dimmers are not supported in version 1 of the driver.
C4 Light Proxy Events:
* Level Changes
Commands
All of the C4 Light Proxy Commands plus the Fade Dimmer C4 Light Proxy command are supported in version 1 of the driver.
Device Specific Commands:
* Fade Dimmer
- Intensity
- Fade Hours
- Fade Minutes
- Fade Seconds
- Delay Hours
- Delay Minutes
- Delay Seconds
* Raise Dimmer
* Lower Dimmer
* Stop Dimmer
* Initialize Light Proxy Data (used in case of connection loss)
Conditionals
All of the C4 Light Proxy Conditions.
Loops
All of the C4 Light Proxy Loops.
To Be Determined.
Device Address
STRING
false
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Initialize Light Proxy Data
InitLightProxy
Fade Dimmer
Fade NAME at PARAM1 Intensity, Fade Time = PARAM2 : PARAM3 : PARAM4, Delay Time = PARAM5 : PARAM6 : PARAM7
Intensity
RANGED_INTEGER
0
100
Fade Hours
RANGED_INTEGER
0
99
Fade Minutes
RANGED_INTEGER
0
59
Fade Seconds
RANGED_INTEGER
0
59
Delay Hours
RANGED_INTEGER
0
99
Delay Minutes
RANGED_INTEGER
0
59
Delay Seconds
RANGED_INTEGER
0
59
Raise Dimmer
Raise NAME
Lower Dimmer
Lower NAME
Stop Dimmer
Stop NAME
Initialize Light Proxy Data
Initialize Light Proxy Data NAME
1
6
Lutron HomeWorksQS Control
1
True
False
False
True
LUTRON_HWQS_DIMMER
True
5001
6
Light
2
False
False
False
False
LIGHT_V2
300
6
ON Button Link
1
False
False
False
True
BUTTON_LINK
301
6
OFF Button Link
1
False
False
False
True
BUTTON_LINK
302
6
Toggle Button Link
1
False
False
False
True
BUTTON_LINK
True
True
True
True
True
False
False
True
False
False
False
True
True
True
False
True