Copyright 2014 HouseLogix Corporation. All rights reserved. Lutron 24 HouseLogix, Inc. 10/06/2009 10:00 PM 09/23/2014 12:00 PM RadioRA2 Dimmer Lights devices_sm/LutronDimmer.gif devices_lg/LutronDimmer.gif Lutron RadioRA2 Dimmer lua_gen light_v2 DriverWorks Lutron RadioRA2 Dimmer Driver Set Version: [v24 rev20151007] ------------------------------------------------------------------------------------------- ONLINE DOCUMENTATION ------------------------------------------------------------------------------------------- Online Support: https://www.lutron.com/ Technical Support: 1.800.523.9466 (24 hours a day / 7 days a week) ------------------------------------------------------------------------------------------- OVERVIEW ------------------------------------------------------------------------------------------- When installing drivers to connect to a Lutron RadioRA2 system, it is recommended that you add the Lutron RadioRA2 Repeater driver first. RadioRA2 Repeater is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers, then the other drivers will be automatically connected to the RadioRA2 Repeater driver. If that driver is not added first, then those connections will need to be made manually. The RadioRA2 Dimmer driver is used to control and monitor any dimmer on the Lutron RadioRA2 system. One driver should be added for each load that is controlled or monitored. When the driver is added it is automatically linked to a RadioRA2 Repeater driver if it exists. If the driver does not exist the connection will need to be made manually after it has been added. Properties Device Address: This is the integration ID or address of the dimmer. Debug Mode: Used for debugging the driver. Output is displayed on the Lua tab. Options: - Off - Print - Log - Print and Log Variables Same as the C4 Light Proxy. Events Since the Lutron RadioRA2 system dimmers only use one button, then the "Top Button" is used for events. * Please note that button press and release events for dimmers are not supported in version 1 of the driver. C4 Light Proxy Events: * Level Changes Commands All of the C4 Light Proxy Commands plus the Fade Dimmer C4 Light Proxy command are supported in version 1 of the driver. Device Specific Commands: * Fade Dimmer - Intensity - Fade Hours - Fade Minutes - Fade Seconds - Delay Hours - Delay Minutes - Delay Seconds * Raise Dimmer * Lower Dimmer * Stop Dimmer * Initialize Light Proxy Data (used in case of connection loss) Conditionals All of the C4 Light Proxy Conditions. Loops All of the C4 Light Proxy Loops. To Be Determined. Device Address STRING false Debug Mode LIST Off Print Log Print and Log Off false Initialize Light Proxy Data InitLightProxy Fade Dimmer Fade NAME at PARAM1 Intensity, Fade Time = PARAM2 : PARAM3 : PARAM4, Delay Time = PARAM5 : PARAM6 : PARAM7 Intensity RANGED_INTEGER 0 100 Fade Hours RANGED_INTEGER 0 99 Fade Minutes RANGED_INTEGER 0 59 Fade Seconds RANGED_INTEGER 0 59 Delay Hours RANGED_INTEGER 0 99 Delay Minutes RANGED_INTEGER 0 59 Delay Seconds RANGED_INTEGER 0 59 Raise Dimmer Raise NAME Lower Dimmer Lower NAME Stop Dimmer Stop NAME Initialize Light Proxy Data Initialize Light Proxy Data NAME 1 6 Lutron RadioRA2 Control 1 True False False True LUTRON_RA2_DIMMER True 5001 6 Light 2 False False False False LIGHT_V2 300 6 ON Button Link 1 False False False True BUTTON_LINK 301 6 OFF Button Link 1 False False False True BUTTON_LINK 302 6 Toggle Button Link 1 False False False True BUTTON_LINK True True True True True False False True False False False True True True False True