Copyright 2014 HouseLogix Corporation. All rights reserved.
Lutron
24
HouseLogix, Inc.
10/06/2009 10:00 PM
09/23/2014 12:00 PM
RadioRA2 Switch
Lights
devices_sm/LutronDimmer.gif
devices_lg/LutronDimmer.gif
Lutron RadioRA2 Switch
lua_gen
light_v2
DriverWorks
Lutron RadioRA2 Switch
Driver Set Version: [v24 rev20151007]
-------------------------------------------------------------------------------------------
ONLINE DOCUMENTATION
-------------------------------------------------------------------------------------------
Online Support: https://www.lutron.com/
Technical Support: 1.800.523.9466 (24 hours a day / 7 days a week)
-------------------------------------------------------------------------------------------
OVERVIEW
-------------------------------------------------------------------------------------------
When installing drivers to connect to a Lutron RadioRA2 system, it is recommended that you add the Lutron RadioRA2 Repeater driver first.
RadioRA2 Repeater is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers,
then the other drivers will be automatically connected to the RadioRA2 Repeater driver. If that driver is not added first, then those connections
will need to be made manually.
The RadioRA2 Switch driver is used to control and monitor any switch on the Lutron RadioRA2 system. One driver should be added for each load that
is controlled or monitored. When the driver is added it is automatically linked to a RadioRA2 Repeater driver if it exists. If the driver does not
exist the connection will need to be made manually after it has been added.
Properties
Device Address:
This is the integration ID or address of the switch.
Debug Mode:
Used for debugging the driver. Output is displayed on the Lua tab.
Options:
- Off
- Print
- Log
- Print and Log
Variables
Same as the C4 Light Proxy.
Events
Since the Lutron RadioRA2 system switches only use one button, then the "Top Button" is used for events.
C4 Light Proxy Events:
* Level Changes
Commands
All of the C4 Light Proxy Commands.
* Initialize Light Proxy Data (used in case of connection loss)
Conditionals
All of the C4 Light Proxy Conditions.
Loops
All of the C4 Light Proxy Loops.
Connections
None
To Be Determined.
Device Address
STRING
false
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Initialize Light Proxy Data
InitLightProxy
Initialize Light Proxy Data
Initialize Light Proxy Data NAME
True
False
False
False
False
True
True
True
False
False
False
False
False
False
False
False
False
False
True
True
1
6
Lutron RadioRA2 Control
1
True
False
False
True
LUTRON_RA2_SWITCH
True
5001
6
Light
2
False
False
False
False
LIGHT_V2
300
6
ON Button Link
1
False
False
False
True
BUTTON_LINK
301
6
OFF Button Link
1
False
False
False
True
BUTTON_LINK
302
6
Toggle Button Link
1
False
False
False
True
BUTTON_LINK