Extra Vegetables Ltd 2012. All rights reserved.TexecomPremier Panels [IP] - FREEPremier Panels [IP]Extra Vegetables Ltd04/03/2012 10:3009/10/2014 12:00800lua_genDriverWorksCopyright Extra Vegetables LTD. All rights reserved.8.0.0
EXTRA VEGETABLES DRIVER FOR TEXECOM PREMIER SECURITY SYSTEMS
This driver connects over Ethernet and requires a IP-COM to be installed in the Texecom central panel.
----------------------------------
BRIEF INSTRUCTIONS
- Install the IP-COM as COM 1 inside the Texecom panel
- First configure it as an 'IP-COM' device and set up a static IP address
- Backup completely out of Engineer mode
- Enter Engineer mode again and set COM 1 to be a 'Crestron System'
- Make the physical connection to the panel and enter the IP address of the panel on the Porperties page.
- Select the correct number of Areas for the panel you are using.
- Select the number of zones that you will be using.
- NEW: Switch to the Actions tab and click Create Zone Contacts
- This creates the contact closures in Composer that you can now assign to PIR or other sensors.
- If you select 'Display Zone Events' then any zone that is triggerd will be shown on the Control4 security panel UI.
- Refresh the navigators
- On the Actions tab select Refresh Area Status and you should see current status on Lua tab.
----------------------------------
FULL INSTRUCTIONS
Full instructions for this driver are included in the download package. You can download the instructions by logging into the Extra Vegetables website at www.extravegetables.com and downloading the driver package.
----------------------------------
SUPPORT
For support on this driver please contact Control4 technical support or your local Control4 distributor.
----------------------------------
AUTO UPDATE
This driver supports Auto Update. To enable this feature select Automatic Updates to 'On' on the Properties page.
----------------------------------
CHANGELOG
8.0.0 Sep 10 2014
Activation key removed
7.1.2 7 July 2014
Ensures that contact sensors are shown closed (non alert) on system reboot.
7.1.1 6 June 2014
Corrects and issue with SMS message sending (yes it took two years for someone to use this feature)
7.1.0 11 March 2014
Adds a property to enable the interval between polling and displaying the keypad information. Increase this value if you are having issues with the panel locking up.
7.0.9 25 Nov 2013
Deals with Control4's unannounced change to the iOS layouts. You will need to resart Director after update to see revised keypad layout.
7.0.8 18 April 2013
User and Tag variables were not being correctly updated when users logged into the panels. This has been corrected.
7.0.7 5 March 2013
Corrects a problem with the serial version of the driver.
7.0.6 28 February 2012
Corrects an issue where incoming messages could become queued up resulting in delays in messages appearing on the UIs.
7.0.5 25 February 2013
Zone contacts were not being restored on Director restart. This version solves this issue. As contacts were being saved correctly updating to this version will preserve the previously defined contact bindings.
7.0.4 31 December 2012
Corrects an authorisation error
7.0.3 30 December 2012
Adds Action to Create Zone Contacts. This prevents zone contacts being overwritten on Auto Update.
You now MUST use this action to create the contacts for the alarm zones on initial installation.
7.0.2 18 December 2012
Works around an issue in Control4 OS 2.3 where <text> appears at the front of messages displayed on the Control4 OS.
7.0.1 5 November 2012
Better handling of user code entry.
Force Area Alarm to false when arming in case this had not be reset correctly.
Monitor panel messages using different pattern to avoid messages being missed.
7.0.0 26 September 2012
Adds driver auto update feature
2 August 2012 - 5.0.7
Corrects an issue where you could not select more than 8 Areas. Only relevant for Premier 168 panels.
3 July 2012 - 5.0.6
Now includes support for IP-Com IP interface as well as Serial connection. Improvement to C4 Controller start up behavior in interrogating for zone status.
3 April 2012 - 5.0.5
Initial release
Driver VersionSTRINGtrueAutomatic UpdatesLISTOffOnOfffalseControl4 MAC AddressSTRINGfalseDriver InformationSTRINGtrueDebug ModeLISTOffOnOfffalseNumber of ZonesRANGED_INTEGER11168falseNumber of AreasRANGED_INTEGER1164falseDisplay Zone EventsLISTYesNoNofalseIP AddressSTRINGfalseIP Port10001STRINGfalsePoll Interval4100STRINGfalseGet Area StatusCheckAreaStatusCreate Zone ContactsCreate Zone ContactsPC OutputSet PC Output PARAM1 to PARAM2 in NAMEOutputRANGED_INTEGER18StateLISTOnOffSend SMS to AllSend SMS message PARAM1 to Registered users in NAMEMessageSTRINGSend SMS to SpecificSend SMS message PARAM1 to PARAM2 in NAMEMessageSTRINGTelNumSTRING{Width=700, Height=336}\x158DVPX777-f.bmp{Width=500, Height=250}\x158dvpx777-b.bmpdevices_sm/security.gifdevices_lg/security.gifSecuritysecurity61Keypad LoginUser logged in via Keypad62Tag LoginUser logged in via Tag63Engineer Logged InEngineer has logged into system64Battery FaultBattery on Security Panel has failed65Fire AlarmFire Alarm triggered66Medical AlarmMedical Alarm Triggered67Panic AlarmPanic Alarm Triggered68Arm FailSystem failed to arm69TamperTamper Alarm50016Security Area A2FalseFalseFalseFalseSECURITYFalse50026Security Area B2FalseFalseFalseFalseSECURITYFalse50036Security Area C2FalseFalseFalseFalseSECURITYFalse50046Security Area D2FalseFalseFalseFalseSECURITYFalse70006Room Selection7FalseFalseFalseFalseTrueSECURITY_SYSTEMFalse0FalseFalseA17