Extra Vegetables Ltd 2012. All rights reserved.TexecomPremier Panels [IP] - FREEPremier Panels [IP]Extra Vegetables Ltd04/03/2012 10:3009/10/2014 12:00800lua_genDriverWorks Copyright Extra Vegetables LTD. All rights reserved. 8.0.0 EXTRA VEGETABLES DRIVER FOR TEXECOM PREMIER SECURITY SYSTEMS This driver connects over Ethernet and requires a IP-COM to be installed in the Texecom central panel. ---------------------------------- BRIEF INSTRUCTIONS - Install the IP-COM as COM 1 inside the Texecom panel - First configure it as an 'IP-COM' device and set up a static IP address - Backup completely out of Engineer mode - Enter Engineer mode again and set COM 1 to be a 'Crestron System' - Make the physical connection to the panel and enter the IP address of the panel on the Porperties page. - Select the correct number of Areas for the panel you are using. - Select the number of zones that you will be using. - NEW: Switch to the Actions tab and click Create Zone Contacts - This creates the contact closures in Composer that you can now assign to PIR or other sensors. - If you select 'Display Zone Events' then any zone that is triggerd will be shown on the Control4 security panel UI. - Refresh the navigators - On the Actions tab select Refresh Area Status and you should see current status on Lua tab. ---------------------------------- FULL INSTRUCTIONS Full instructions for this driver are included in the download package. You can download the instructions by logging into the Extra Vegetables website at www.extravegetables.com and downloading the driver package. ---------------------------------- SUPPORT For support on this driver please contact Control4 technical support or your local Control4 distributor. ---------------------------------- AUTO UPDATE This driver supports Auto Update. To enable this feature select Automatic Updates to 'On' on the Properties page. ---------------------------------- CHANGELOG 8.0.0 Sep 10 2014 Activation key removed 7.1.2 7 July 2014 Ensures that contact sensors are shown closed (non alert) on system reboot. 7.1.1 6 June 2014 Corrects and issue with SMS message sending (yes it took two years for someone to use this feature) 7.1.0 11 March 2014 Adds a property to enable the interval between polling and displaying the keypad information. Increase this value if you are having issues with the panel locking up. 7.0.9 25 Nov 2013 Deals with Control4's unannounced change to the iOS layouts. You will need to resart Director after update to see revised keypad layout. 7.0.8 18 April 2013 User and Tag variables were not being correctly updated when users logged into the panels. This has been corrected. 7.0.7 5 March 2013 Corrects a problem with the serial version of the driver. 7.0.6 28 February 2012 Corrects an issue where incoming messages could become queued up resulting in delays in messages appearing on the UIs. 7.0.5 25 February 2013 Zone contacts were not being restored on Director restart. This version solves this issue. As contacts were being saved correctly updating to this version will preserve the previously defined contact bindings. 7.0.4 31 December 2012 Corrects an authorisation error 7.0.3 30 December 2012 Adds Action to Create Zone Contacts. This prevents zone contacts being overwritten on Auto Update. You now MUST use this action to create the contacts for the alarm zones on initial installation. 7.0.2 18 December 2012 Works around an issue in Control4 OS 2.3 where <text> appears at the front of messages displayed on the Control4 OS. 7.0.1 5 November 2012 Better handling of user code entry. Force Area Alarm to false when arming in case this had not be reset correctly. Monitor panel messages using different pattern to avoid messages being missed. 7.0.0 26 September 2012 Adds driver auto update feature 2 August 2012 - 5.0.7 Corrects an issue where you could not select more than 8 Areas. Only relevant for Premier 168 panels. 3 July 2012 - 5.0.6 Now includes support for IP-Com IP interface as well as Serial connection. Improvement to C4 Controller start up behavior in interrogating for zone status. 3 April 2012 - 5.0.5 Initial release Driver Version STRING true Automatic Updates LIST Off On Off false Control4 MAC Address STRING false Driver Information STRING true Debug Mode LIST Off On Off false Number of Zones RANGED_INTEGER 1 1 168 false Number of Areas RANGED_INTEGER 1 16 4 false Display Zone Events LIST Yes No No false IP Address STRING false IP Port 10001 STRING false Poll Interval 4100 STRING false Get Area Status CheckAreaStatus Create Zone Contacts Create Zone Contacts PC Output Set PC Output PARAM1 to PARAM2 in NAME Output RANGED_INTEGER 1 8 State LIST On Off Send SMS to All Send SMS message PARAM1 to Registered users in NAME Message STRING Send SMS to Specific Send SMS message PARAM1 to PARAM2 in NAME Message STRING TelNum STRING {Width=700, Height=336}\x158DVPX777-f.bmp{Width=500, Height=250}\x158dvpx777-b.bmpdevices_sm/security.gifdevices_lg/security.gif Security security 61 Keypad Login User logged in via Keypad 62 Tag Login User logged in via Tag 63 Engineer Logged In Engineer has logged into system 64 Battery Fault Battery on Security Panel has failed 65 Fire Alarm Fire Alarm triggered 66 Medical Alarm Medical Alarm Triggered 67 Panic Alarm Panic Alarm Triggered 68 Arm Fail System failed to arm 69 Tamper Tamper Alarm 5001 6 Security Area A 2 False False False False SECURITY False 5002 6 Security Area B 2 False False False False SECURITY False 5003 6 Security Area C 2 False False False False SECURITY False 5004 6 Security Area D 2 False False False False SECURITY False 7000 6 Room Selection 7 False False False False True SECURITY_SYSTEM False 0 False False A17