Copyright 2019 Control4 Corporation. All Rights Reserved. HeatMiser Network Thermostat (No Schedule) Network Thermostat (No schedule) Control4 04/02/2011 16:30 05/21/2019 12:00 801 lua_gen DriverWorks devices_sm/control4_thermostat_16.gif devices_lg/control4_thermostat_32.gif control4_thermostat_proxy Copyright 2019 Control4 Corporation. All Rights Reserved. 8.0.1 EXTRA VEGETABLES DRIVER FOR HEATMISER NETWORK THERMOSTAT WITH UH1 WIRING CENTRE This driver enables Heatmiser UH1 underfloor heating to be integrated with Control4. This driver is for the Non-Programmable thermostats ONLY. It does not support scheduling or hot water. Do NOT use this driver with a programmable thermostat You cannot use the Heatmiser Colour Touch Pad or Network Monitor with this integration. ---------------------------------- BRIEF INSTRUCTIONS - Configure the master UH-1 driver and interface unit. - Set up each thermostat on the UH1. Ensure that each has a UNIQUE ID number. This includes any hotwater time switch that is not part of the integration. Remember two zone thermostats must be set up with a different ID for each zone. - Set the Thermostat scheduling on the units themselves into 7 day mode NOT the defualt 5/2 mode. - Make Composer connections to set the Thermostat as the Temperature Display and Temperature Control device for the appropriate room(s) - Ensure that this driver is connected to the main Heatmiser UH1 driver. - For two zone thermostats use two separate copies of this driver in the project. - Enter the unique ID number of this thermostat on the Properties page. - Finalise the setting up of the master UH1 driver and test. ---------------------------------- UPDATING FROM VERSIONS PRIOR TO 7.0.0 The usual quick update procedure DOES NOT WORK. First make a note of the ID numbers for each thermostat currently in the project. Delete all the Heatmiser thermostats from the project. Restart the Controller Add and configure the new version 7 drivers in the project. Remember to make the Temperature and Temperature Control connections. Refresh the Navigators ---------------------------------- SUPPORT For support on this driver please contact Control4 technical support or your local Control4 distributor. ---------------------------------- CHANGELOG 8.0.1 May 21 2019 Fixed some bugs. 8.0.0 Sep 10 2014 Activation key removed. 7.1.6 - January 23 2014 Minor fix on calculating expected temperature from schedule. Not relevant to this driver. 7.1.5 - 16 December Corrects an issue with time sync when Linux system is using 12 hour clock mode. 7.1.4 - 6 Novmeber 2013 Corrects an issue in locales where the decimal separator is , 7.1.3 - 17 October 2013 Introduces version for Thermostats that do no have programming (scheduling features). These also do not have hot water control. 7.1.2 - 2 October 2013 Corrects an error where the 5/2 warning message appeared would not clear. 7.1.1 - 25 Sep 2013 Corrects an error where the time sync on Sunday was incorrect. 7.1.0 - 11 Sep 2013 No longer tries to change mode to 7 day as this caused issues. Will report in driver information is mode is incorrect. This must be physically changed on thermostat. 7.0.9 - 17 June 2013 Automatically sets TStat to 7 day mode if it is found to be in 5/2 Mode. 7.0.7 - 9 Apr 2013 Compatible with changed isEnabled notification in OS 2.4 Changes made to help prevent 'Varies' being incorrectly shown when updating the schedule on a touchpanel. 7.0.6 - 18 Feb 2013 NEW FEATURE Synchronises clock on start up and then between 3am and 4am and on license checkin thereafter. This also provides automatic daylight savings adjustment. 7.0.5 - 11 Feb 2013 Adds pacing to commands for newer contollers. 7.0.4 - 18 Jan 2013 Fixed problem in parsing of schedule that would cause stat to stop giving feedback. 7.0.3 - 28 Nov 2012 Updates polling time based on number of Thermostats defined in serial and network master drivers. No change to this driver. 7.0.2 Nov 13 2012 Updates parsing code in serial and network master drivers. No change to this driver. 7.0.1 Nov 5 2012 Change in master driver for serial version only. 7.0.0 Oct 5 2012 Release supports Auto Update. Thermostat driver name changed to ensure compatibility with HTML version of 4Site. 5.0.7 - 22 June 2012 Now supports new White labeled Serial-IP interface. PLEASE READ UPDATED INSTRUCTIONS CAREFULLY. 5.0.6 - 19 March 2012 Resolves issue with selecting a time in a schedule that was ending in 15/45 (forces to 00/30). 5.0.5 - 21 December 2011 Adds better support for activation/checking on controllers that may have unreliable internet connection. 5.0.1 - 14 November 2011 Supports bundle license for Heatmiser/Coolmaster/Thermostat Controller driver. No functional changes or requirement to upgrade from 5.0.0. 5.0.0 - 7 October 2011 Version REQUIRED for use with new license key system. No other changes from previous version. 2.1.1 - 5 July 2011 Fixed bug where status was always sent to Control4 to only send status on change; larger Heatmiser systems should now work better with slave controllers running OSDs. 2.1.0 - 4 May 2011 Enabled scheduling support to and from the Heatmiser system. Allows you to set schedules either on the Control4 or Heatmiser interfaces and the information will be communicated to the other system. 2.0.1 - 4 Apr 2011 Resolved polling problems on larger systems. Note: Cannot use Heatmiser color touchpad with Control4 driver. Driver Version STRING true Debug Mode LIST Off On Off false Driver Information STRING true Thermostat ID RANGED_INTEGER 1 32 1 HOT_WATER_ON Hot Water On on NAME HOT_WATER_AUTO Hot Water Auto (Follow schedule) on NAME HOT_WATER_OFF Hot Water Off on NAME Comfort 1 HOT_WATER_ON Hot Water is On now on NAME 2 HOT_WATER_OFF Hot Water is Off now on NAME 1 1 6 Management Link False False False False 43123 True HEATMISER_CONTROL 5001 6 THERMOSTAT 2 False False False False THERMOSTAT 7000 6 Room Selection 7 False False False False False TEMPERATURE False TEMPERATURE_CONTROL True False False False 41 95 41 95 50 350 50 350 False Off,Heat Off,Heat True True True False False True False True False