Copyright 2015 Control4 Corporation. All rights reserved.Extra VegetablesThermostat Controller - FREEThermostat ControllerExtra Vegetables11/14/2011 12:0008/24/2015 16:00803lua_genDriverWorks Copyright 2015 Control4 Corporation. All rights reserved. 8.0.3 EXTRA VEGETABLES DRIVER FOR COMBINING THERMOSTATS This driver allows you to combine thermostats to provide a single control interface on the Control4 UI. It can be used in one of two ways: 1) To combine heating, cooling or auto thermostats from two different systems. The driver can unify the set points, provide a dead zone and prevent the systems fighting. 2) Combining multiple thermostats across a building. In this way it creates a 'master thermostat'. Individual thermostats can still be controlled but if the master thermostat is adjusted the new settings will be sent to all other associated thermostats. This is one driver where you are really going to need to read the full instructions. ---------------------------------- BRIEF INSTRUCTIONS - Select the thermostats you wish to combine. - If combining two thermostats in the same room, hide the original thermostats from the Navigators. - If combining two thermostats in the same room set the offset and dead zone you require. - Select a thermostat whose temperature will be displayed on the Control4 UIs. - Use the Actions Tab to Push the Settings and Schedule to the controlled thermostats. ---------------------------------- FULL INSTRUCTIONS Full instructions for this driver are included in the download package. You can download the instructions by logging into the Extra Vegetables website at www.extravegetables.com and downloading the driver package. ---------------------------------- SUPPORT For support on this driver please contact Control4 technical support or your local Control4 distributor. ---------------------------------- AUTO UPDATE This driver supports Auto Update. To enable this feature select Automatic Updates to 'On' on the Properties page. ---------------------------------- CHANGELOG 8.0.3 Jul 24 2015 OS2.7 was forcing a deadband between Heat and Cool which caused issues with CoolMaster. Requires Director restart - but if you see this that has been done. 8.0.2 Jan 5 2015 Removed "Auto, On" fan mode option and replaced with "Auto, High, Medium, Low" fan modes; added support for passthrough to all selected thermostats. 8.0.1 Sep 19 2014 Startup procedure altered to wait for project initialization before running. 8.0.0 Sep 10 2014 Activation key removed 7.0.8 - December 2013 Works round an issue with some locales where all times were being sent in 12h format 7.0.7 - 20 November 2013 Minor bug fix 7.0.6 - October 2013 Includes a version of the driver with no scheduling capabilities. 7.0.5 - 23 July 2013 Resolves issue with push overwriting button lock, remote sensor and vacation settings on target thermostats 7.0.4 - 23 July 2013 Resolves issue with thermostat not controlling in some situations. 7.0.3 - 10 May 2013 Persists settings over controller reboot. Added action to simply push all settings and schedule from this driver to controlled thermostats. Can control via the feedback thermostat. Handles single set point Auto thermostats better such as Coolmaster 7.0.2 - 29 April 2013 Compatible with changed isEnabled notification in OS 2.4 7.0.1 - 5 February 2013 Corrects an issue where the current temperature would not display correctly on Controller reboot. Immediately displays current temperature when Feedback thermostat is selected. 7.0.0 - 4 October 2012 Supports auto update. Name changed to ensure compatibility with HTML version of 4Sight. 5.0.5 - 21 December 2011 Adds better support for activation/checking on controllers that may have unreliable internet connection. 5.0.1 - 14 November 2011 Initial release. Driver Version STRING true Automatic Updates LIST Off On Off false Control4 MAC Address STRING false Driver Information STRING true Debug Mode LIST Off On Off false Auto Thermostat(s) DEVICE_SELECTOR control4_thermostat_proxy.c4i True Cooling (Cool on Auto) Thermostat(s) DEVICE_SELECTOR control4_thermostat_proxy.c4i True Cool Setpoint Offset for Auto stats (F) 0 STRING false Heating (Heat on Auto) Thermostat(s) DEVICE_SELECTOR control4_thermostat_proxy.c4i True Heat Setpoint Offset for Auto stats (F) 0 STRING false Feedback Thermostat DEVICE_SELECTOR control4_thermostat_proxy.c4i False Dead zone (F) 3 STRING false Dual setpoint in Auto Mode LIST Yes No Yes false Allow control from Feedback thermostat LIST No Heating Settings Cooling Settings Both Settings Yes false Auto mode schedule LIST Heat Setpoints Cool Setpoints Heat Setpoints false Push Schedule Push Schedule from NAME to controlled thermostats Push Settings Push Settings from NAME to controlled thermostats Push to thermostats PUSH Comfort control4_thermostat_proxy 5001 6 THERMOSTAT 2 False False False False THERMOSTAT 7000 6 Room Selection 7 False False False False False TEMPERATURE False TEMPERATURE_CONTROL True True True 10 390 10 390 True Off,Heat,Cool,Auto,Emergency Heat Auto,Low,Medium,High Off,2 Hours,Until Next,Permanent Off,Heat,Cool,Auto Off,On True True True True True True True True True 0 0