Copyright 2015 Control4 Corporation. All rights reserved.Extra VegetablesThermostat Controller - FREEThermostat ControllerExtra Vegetables11/14/2011 12:0008/24/2015 16:00803lua_genDriverWorks
Copyright 2015 Control4 Corporation. All rights reserved.
8.0.3
EXTRA VEGETABLES DRIVER FOR COMBINING THERMOSTATS
This driver allows you to combine thermostats to provide a single control interface on the Control4 UI.
It can be used in one of two ways:
1) To combine heating, cooling or auto thermostats from two different systems. The driver can unify the set points, provide a dead zone and prevent the systems fighting.
2) Combining multiple thermostats across a building. In this way it creates a 'master thermostat'. Individual thermostats can still be controlled but if the master thermostat is adjusted the new settings will be sent to all other associated thermostats.
This is one driver where you are really going to need to read the full instructions.
----------------------------------
BRIEF INSTRUCTIONS
- Select the thermostats you wish to combine.
- If combining two thermostats in the same room, hide the original thermostats from the Navigators.
- If combining two thermostats in the same room set the offset and dead zone you require.
- Select a thermostat whose temperature will be displayed on the Control4 UIs.
- Use the Actions Tab to Push the Settings and Schedule to the controlled thermostats.
----------------------------------
FULL INSTRUCTIONS
Full instructions for this driver are included in the download package. You can download the instructions by logging into the Extra Vegetables website at www.extravegetables.com and downloading the driver package.
----------------------------------
SUPPORT
For support on this driver please contact Control4 technical support or your local Control4 distributor.
----------------------------------
AUTO UPDATE
This driver supports Auto Update. To enable this feature select Automatic Updates to 'On' on the Properties page.
----------------------------------
CHANGELOG
8.0.3 Jul 24 2015
OS2.7 was forcing a deadband between Heat and Cool which caused issues with CoolMaster. Requires Director restart - but if you see this that has been done.
8.0.2 Jan 5 2015
Removed "Auto, On" fan mode option and replaced with "Auto, High, Medium, Low" fan modes; added support for passthrough to all selected thermostats.
8.0.1 Sep 19 2014
Startup procedure altered to wait for project initialization before running.
8.0.0 Sep 10 2014
Activation key removed
7.0.8 - December 2013
Works round an issue with some locales where all times were being sent in 12h format
7.0.7 - 20 November 2013
Minor bug fix
7.0.6 - October 2013
Includes a version of the driver with no scheduling capabilities.
7.0.5 - 23 July 2013
Resolves issue with push overwriting button lock, remote sensor and vacation settings on target thermostats
7.0.4 - 23 July 2013
Resolves issue with thermostat not controlling in some situations.
7.0.3 - 10 May 2013
Persists settings over controller reboot.
Added action to simply push all settings and schedule from this driver to controlled thermostats.
Can control via the feedback thermostat.
Handles single set point Auto thermostats better such as Coolmaster
7.0.2 - 29 April 2013
Compatible with changed isEnabled notification in OS 2.4
7.0.1 - 5 February 2013
Corrects an issue where the current temperature would not display correctly on Controller reboot.
Immediately displays current temperature when Feedback thermostat is selected.
7.0.0 - 4 October 2012
Supports auto update.
Name changed to ensure compatibility with HTML version of 4Sight.
5.0.5 - 21 December 2011
Adds better support for activation/checking on controllers that may have unreliable internet connection.
5.0.1 - 14 November 2011
Initial release.
Driver Version
STRING
true
Automatic Updates
LIST
- Off
- On
Off
false
Control4 MAC Address
STRING
false
Driver Information
STRING
true
Debug Mode
LIST
- Off
- On
Off
false
Auto Thermostat(s)
DEVICE_SELECTOR
- control4_thermostat_proxy.c4i
True
Cooling (Cool on Auto) Thermostat(s)
DEVICE_SELECTOR
- control4_thermostat_proxy.c4i
True
Cool Setpoint Offset for Auto stats (F)
0
STRING
false
Heating (Heat on Auto) Thermostat(s)
DEVICE_SELECTOR
- control4_thermostat_proxy.c4i
True
Heat Setpoint Offset for Auto stats (F)
0
STRING
false
Feedback Thermostat
DEVICE_SELECTOR
- control4_thermostat_proxy.c4i
False
Dead zone (F)
3
STRING
false
Dual setpoint in Auto Mode
LIST
- Yes
- No
Yes
false
Allow control from Feedback thermostat
LIST
- No
- Heating Settings
- Cooling Settings
- Both Settings
Yes
false
Auto mode schedule
LIST
- Heat Setpoints
- Cool Setpoints
Heat Setpoints
false
Push Schedule
Push Schedule from NAME to controlled thermostats
Push Settings
Push Settings from NAME to controlled thermostats
Push to thermostats
PUSH
Comfort
control4_thermostat_proxy
5001
6
THERMOSTAT
2
False
False
False
False
THERMOSTAT
7000
6
Room Selection
7
False
False
False
False
False
TEMPERATURE
False
TEMPERATURE_CONTROL
True
True
True
10
390
10
390
True
Off,Heat,Cool,Auto,Emergency Heat
Auto,Low,Medium,High
Off,2 Hours,Until Next,Permanent
Off,Heat,Cool,Auto
Off,On
True
True
True
True
True
True
True
True
True
0
0