HomeWorks QS HVAC Controller
Comfort
devices_sm/control4_thermostat_16.gif
devices_lg/control4_thermostat_32.gif
HomeWorks QS HVAC Controller
lua_gen
control4_thermostat_proxy
DriverWorks
Lutron HomeWorks QS HVAC Controller
[v1 rev 20121005]
When installing drivers to connect to a Lutron HomeWorks QS system, it is recommended that you add the Lutron HomeWorks QS Processor driver first. HomeWorks QS Processor is a singleton driver and can be added only once in a project. If this driver exists prior to adding any of the other drivers, then the other drivers will be automatically connected to the HomeWorks QS Processor driver. If that driver is not added first, then those connections will need to be made manually.
The HomeWorks QS HVAC Controler driver is used to control and monitor an HVAC system on the Lutron HomeWorks QS system. When the driver is added it is automatically linked to a HomeWorks QS Processor driver if it exists. If the driver does not exist the connection will need to be made manually after it has been added.
Properties
Device Address:
This is the integration ID or address of the HVAC controller.
Debug Mode:
Used for debugging the driver. Output is displayed on the Lua tab.
Options:
Off
Print
Log
Print and Log
Variables
Same as the C4 Thermostat Proxy.
Events
All of the C4 Thermostat Proxy Events.
Device Specific Events:
* Eco Mode Off
* Eco Mode On
* Sensor Connection Normal
* Sensor Connection No Sensor
* Sensor Connection Wired
Commands
All of the C4 Thermostat Proxy Commands.
Device Specific Commands:
* Set Eco Mode
- Mode (Off/On)
Conditionals
All of the C4 Thermostat Proxy Conditions.
Loops
All of the C4 Thermostat Proxy Loops.
To Be Determined.
Device Address
STRING
false
Debug Mode
LIST
- Off
- Print
- Log
- Print and Log
Off
false
Init Thermostat Data
InitTstatProxy
Set Eco Mode
Set Eco mode: PARAM1 on NAME
Mode
LIST
- On
- Off
1
6
Lutron HomeWorks QS Control
1
True
False
False
True
LUTRON_HWQS_HVAC
True
5001
6
Thermostat
2
False
False
False
False
THERMOSTAT
False
7000
6
Room Selection
7
False
False
False
False
True
TEMPERATURE
True
TEMPERATURE_CONTROL
1
Eco Mode Off
When NAME Eco mode is disabled
2
Eco Mode On
When NAME Eco mode is enabled
3
Sensor Connection Normal
When NAME sensor connection normal
4
Sensor Connection No Sensor
When NAME sensor connection no sensor
5
Sensor Connection Wired
When NAME sensor connection wired
True
True
True
False
Off,Heat,Cool,Auto,Emergency Heat
Auto,On
Off,Until Next,Permanent
Off,Heat,Cool
Off,On
False
False
True
False
True
True
False
True
False