Copyright 2021 SnapAV. All rights reserved.SnapAVWattBoxWB-300-IP-3WB-300-IP-309/01/2015 2:10 PM3/29/2021 5:00 PM3lua_genrelayDriverWorksTrue wattbox_wb300ip3 wattbox:wb300ip3 0 0 0 0 1 6 Relay 1 1 False False False True RELAY 2 6 Relay 2 1 False False False True RELAY 3 6 Relay 3 1 False False False True RELAY 5000 6 WATTBOX WB-300-IP-3 2 False False False False 6001 1 Ethernet 4 True False False True TCP 80 True True True True Copyright 2019 SnapAV. All rights reserved. 2.0 AlwaysOn00False CHANGE LOG v3 Updated connection binding to suppress events v2 Fixed SDDP IP Address Aded device spefic commands for missing outlets v1 Release WATTBOX IP CONFIGURATION FOR CONTROL4: Setup WATTBOX Network settings: 1) Connect the WATTBOX to the network via RJ45/CAT5. 2) Login to the WATTBOX and access the Setup/Network menu. 3) Setup a Static IP address: - Enter desired addresses IP Address, Net Mask, Gateway and DNS. - IP Address - Subnet Mask - Default Gateway - Obtain an IP address - Set this to Manual - Primary DNS Server IP - Secondary DNS Server IP - Obtain DNS Server - Set this to Manual - Click "Apply" to confirm. The system will reboot - Review the Network settings and verify all addresses are correct. COMPOSER CONFIGURATION: Enter IP Address of the WATTBOX into Composer: 1) In the Composer/System Design/System column tab, select the WATTBOX. 2) In the Composer/Properties/Properties tab, enter the static IP address of the WATTBOX in the IP Address field, then click on SET. 3) In the Username field, enter your Username (Default is *admin*), then click on SET. 4) In the Password field, enter your password (Default is *blank*), then click on SET. NOTE: The Username and Password above are used only to allow Director to establish a network control session (much like RS232 or IR). This is not considered to be a secure function and does not require secure Usernames or Passwords. 5) Verify the WATTBOX is connected to Director by reviewing the Composer/Properties/Properties tab "Driver Information" field. - When properly configured and connected it will read "Got status ok". - When not properly connected, the "Driver Information" field will show Valid IP address (This doesn't mean it is connected) 6) If you have changed the HTTP Port in the WATTBOX configuration then you will need to set the "Port" field to the same as the WATTBOX. CONTROL AND CONNECTIONS: 1) In the Composer/ Connections you will need to bind the outlet relays to Relay input Devices for operation. CUSTOM PROGRAMMING: There are custom programming commands to power cycle an outlet, and enable or disable the auto reboot feature. The cycle all outlets command will only execute if at the point of execution all the outlets are On. Cycle Outlet 1 Cycle power on outlet 1 on NAME Cycle Outlet 2 Cycle power on outlet 2 on NAME Cycle Outlet 3 Cycle power on outlet 3 on NAME Auto Reboot Set Auto Reboot to PARAM1 on NAME State LIST False On Off Cycle All Outlets Cycle power on all outlets on NAME Control4 MAC Address STRING false Driver Information STRING true Debug Mode LIST false Off Off On Username STRING false admin Password STRING false 1234 IP Address STRING false Port STRING false 80 Polling Frequency STRING false 10